BMS-HVAC Products from VCP Sweden


NEW -
Touch Screen Thermostats TTH 8-series





Read more about
NEW: on/off Touch Screen Thermostats TTH 8D-series

Read more about
NEW: 0-10 Vdc Touch Screen Thermostats TTH 8M-series


NEW -
Duct Carbon Dioxide (CO2) transmitter CO2D-series
with Excellent features

Duct Carbon Dioxide CO2 transmitter CO2D-series width=

Read more about
NEW - Duct Carbon Dioxide (CO2) transmitter CO2D-series


NEW -
Water Warning Leakage Detector WLD 24

Read more about
NEW - Water Warning Leakage Detector WLD 24


NEW -
Particle Meter transmitter PMR-series
with Excellent features

Room Particle Matter Transmitter PMR-series width=

Read more about
NEW - Particle Meter transmitter PMR-series


NEW -
Duct Air Quality (VOC) transmitter VOCD-series
with Excellent features

Duct Air Quality (VOC) transmitter VOCD-series width=

Read more about
NEW - Duct Air Quality (VOC) transmitter VOCD-series


NEW -
Room Air Quality (VOC) transmitter VOCR-series
with Excellent features

Room Air Quality (VOC) transmitter VOCR-series width=

Read more about
NEW - Room Air Quality (VOC) transmitter VOCR-series


NEW -
Room Carbon Dioxide (CO2) transmitter CO2R-series
with Excellent features

Room CO2 transmitter CO2R -series width=

Read more about
NEW - Room Carbon Dioxide (CO2) transmitter CO2R-series


NEW - IP rating,
Air Differential Pressure Switch 930-series
with IP65 protection

Read more about
NEW - Air Differential Pressure Switch 930-series with IP65 protection


NEW - Air Velocity Transmitters AVT-series

Read more about
NEW - Air Velocity Transmitters AVT-series


New colored LCD display for room Carbon Dioxide (CO2) + Humidity (rH) + Temperature (T) transmitter RCD 010 THD.

The colored LCD display for room Carbon Dioxide (CO2) + Humidity (rH) + Temperature (T) transmitter RCD 010 THD show actual value of each parameter CO2+rH+T.

The room Carbon Dioxide (CO2) + Humidity (rH) + Temperature (T) transmitter RCD 010 THD have 3 analogue outputs, i.e. one 0-10 Vdc output for each parameter CO2+rH+T.

Selectable ranges for Carbon Dioxide (CO2) + Humidity (rH) + Temperature (T)
with DIP switches on pcb.

Read more about
the room Carbon Dioxide (CO2) + Humidity (rH) + Temperature (T) transmitter
RCD 010 THD


New features on Carbon Monoxide (CO) Gas Detector COW.

The new features on the Carbon Monoxide (CO) Gas Detector
COW 1351 MDR2B:
2 x Relays outputs and Buzzer.

  • Electrochemical sensor (replaceable)
  • Measuring ranges 0-50 ppm, 0-100 ppm, 0-200 ppm or 0-300 ppm
    (DIP switches)
  • Two outputs: 4-20 mA and 0-10 Vdc
  • t90 < 50 sec.
  • Sensor life time 6 years
  • IP65 for enclosure, IP41 for probe
  • Power supply 24 Vac/dc
  • Modbus RS485
  • LCD Display
  • 2 x Relays outputs
  • Buzzer

Read more about
Carbon Monoxide (CO) Gas Detectors COW


NEW - Room Carbon Dioxide (CO2) transmitter
CDR 010N

Room Carbon Dioxide(CO2)transmitter CDR 010N

Room Carbon Dioxide (CO2) transmitter
CDR 010N

The room Carbon Dioxide (CO2) transmitter CDR 010N is a maintenance-free microprocessor-controlled with automatic calibration (fixed) and used for recording the CO2 content of the air within a range of 0-2000 ppm.

The measurement value 0-2000 ppm for room Carbon Dioxide (CO2) transmitter CDR 010N is converted into standard signal of 0-10 Vdc.

Read more about room Carbon Dioxide (CO2) transmitter CDR 010N


NEW - Liquid Static Pressure Transmitter
PLTS

Liquid Static Pressure Transmitter
PLTS-series

For measuring relative pressure of non-aggressive media

0-10 Vdc output (3-wire) and 4-20 mA output (2-wire)

Pressure range 0-10 Bar, other pressure ranges on request

G1/4” connection thread and G1/2” connection thread

Read more about Liquid Static Pressure Transmitter PLTS-series


NEW - Air Differential Pressure Transmitter
PTO 500V

• PTO 500V is a new low cost Air Differential Pressure Transmitter
with analog output 0-10 Vdc and pressure range 0-500 Pa.

• Other analog outputs and other pressure ranges on request.

• PTO-series are ideal for measuring filter conditions, as well as many other applications in ventilation/air conditioning systems in buildings, laboratory’s
and clean rooms, non-combustible and non aggressive media.

• Duct Fixing Kit DFK 200 for Air Differential Pressure Transmitter PTO
Duct Fixing Kit DFK 200 includes:
2 plastic tubes with integrated mounting plate,
2 metres PVC hose and
4 screws

Read more about
Air Differential Pressure Transmitter PTO


NEW - Zone Valves and Actuators
VZ-series and AZ-series

Zone Valves VZ-series and Actuators AZ-series

The Zone Valves VZ-series and Actuators AZ-series
to be applied in hot and chilled applications.

Valves

  • 2 way, 3-way and 3-way with 4 port
  • Sizes DN15 and DN20 (1/2" and 3/4")
  • Kvs values from 0.25 up to 6.0
  • Stroke lenght 2.5 mm

Actuators

  • Actuating force 140 N
  • Control Signals
    On/Off , PWM (Pulse With Modulation ) or 0-10 Vdc
  • Stroke lenght 2.5 mm

Read more about Zone Valves VZ-series and Actuators AZ-series


NEW - Flexible & Multi Functional
Air Differential Pressure Transmitter
PAT-series

• DIP-switches on PCB to select
Pressure Range, Pressure Unit and Response Time

• High accuracy +/-1%

• Power Supply and Output
16-30 Vac/dc with 0-10 Vdc (3-wire) for PAT 010D
12-30 Vdc with 4-20 mA (2-wire) for PAT 420D

• LCD digital display

• Including duct mounting set

Read more about Air Differential Pressure Transmitters PAT-series


Ventilation Control Products (VCP) supply products for
HVAC Automation / Building Automation.

Our product range contains:

Sensors, Transmitters, Switches and Detectors for
Temperature, Humidity, Pressure, Air Quality (VOC), Carbon Dioxide (CO2), Carbon Monoxide (CO), Liquid, Smoke and Weather.

Including Zone Valves, Valve Actuators, Damper Actuators, Controllers and Thermostats.

VCP products are designed and used as field control products to be integrated with HVAC control systems such as:

  • BAS = Building Automation System
  • BMS = Building Management System
  • BEMS = Building Energy Management System
  • BAMS = Building Automation Management Systems
  • DDC = Direct Digital Controls
  • FMS = Facility Management Systems
  • FMIS = Facility Management Information Systems
  • HVAC controls = Heating, Ventilation and Air Conditioning controllers

HVAC Sensors and Transducers

Temperature Monitoring

  • Room, Duct, Immersion, Strap-on and Outdoor temperature sensors, transmitters/transducers.
  • Designed and used to sense temperature in in heating, ventilation and air conditioning systems.
  • Sensors with direct output
    Thermistors, Platina, Nickel
    NTC 10K, NTC 1.8K, NTC 20K, PT1000, PT100, NI1000, NI1000 TK5000, PTC
    sensing elements.
  • Transmitters with output 0-10 Vdc or 4-20 mA, with or without LCD display.

Humidity Monitoring

  • Room, Duct and Outdoor RH transmitters/transducers and hygrostats/humidistats.
  • The humidity and temperature transmitters measures the relative humidity and temperature, designed and used to sense temperature in in heating, ventilation and air conditioning systems.
  • Output 0-10 Vdc or 4-20 mA, with or without LCD display.

Pressure Monitoring

  • Pressure switches and pressure transmitters for static, over, differential pressure and vaccum.
  • Switches, where switching pressure can easily be adjusted on a scaled adjustment knob.
  • 20-200 Pa, 20-300 Pa, 30-400 Pa, 50-500 Pa, 200-1000 Pa, 500-2500 Pa, 1000-4000 Pa.
  • Transmitters/Transducers, output 0-10 Vdc or 4-20 mA, with or without LCD display.
  • 0-100 Pa, 0-250 Pa, 0-500 Pa, 0-1000 Pa, 0-2500 Pa, 0-5 kPa, 0-10 kPa,
    0-25 kPa, 0-50 kPa, 0-100 kPa and 0-250 kPa.

Flow Monitoring

Air Flow Paddle Switch intended to monitor air flow and non-agressive gaseous within a duct and provides a switched output on detection of either a specified air velocity or flow failure.

Air Quality (VOC) Monitoring

  • VOC = Volatile Organic Compounds.
  • Also named a Mixed Gas Sensor.
  • Used for better Indoor Climate and Energy Savings.
  • Room and Duct transmitters/transducers.
  • Output 0-10 Vdc or 4-20 mA, with or without LCD display.

Carbon Dioxide (CO2) Monitoring

  • Used for Field Controls in Green Building Applications.
  • Room and Duct transmitters/transducers.
  • Output 0-10 Vdc or 4-20 mA, with or without LCD display.

Carbon Monoxide (CO) Detection

  • CO detectors/transmitters/transducers to be used to detect toxic gas Carbon Monoxide  
  • In applications suchvehicle exhaust in parking structures,
    (e.g. underground garages), engine repair shops, tunnels, equipment rooms, ventilation systems etc.
  • Electrochemical sensor element.
  • Output 4-20 mA or 2-10 Vdc.

Liquid Detection

  • Liquid Warning Detectors and
    Alarm Band for Detection of Moisture and Water
  • Early detection means Early warning.
  • Avoid leak damages.
  • Detect moisture and liquid.
  • Use VCP´s detectors and alarm band to prevent or minimize water damages.

Smoke Detection

  • Duct Smoke Detectors for Ventilation Systems.
  • The primary purpose of duct smoke detection is to prevent injury, panic, and property damage by reducing the spread (recirculation) of smoke.
  • Detection of smoke is achieved by monitoring a carefully controlled infrared beam within a perforated tube which is inserted into the ductwork.
  • This method senses smoke directly within the duct, eliminating the problems associated with conventional detectors mounted in sampling boxes.
  • IR-detection (obscuration).
  • Probe lengths 300 mm and 600 mm.

Controllers

  • Zone Controllers with LCD display.
  • Full-featured CPU based controller designed for small sized cooling and heating air handling systems in residential and commercial facilities.
  • 230 Vac or 24 Vac fan speed control.
  • single or 3 speed (High-Med-Low).
  • 0-10 Vdc analogue and on/off outputs.
  • Cooling and heating.

Thermostats (Fan Coil)

  • Room thermostats designed for line voltage or low voltage control of valves, relays and fan motors
  • in fan coil units for commercial, industrial and residential installations.
  • Fan speed switch.
  • 3 speed (HIGH-MED-LOW).
  • 24 V and 220 V versions.
  • On/off,heat only or cool only, 2-pipe systems.
  • Heat-off-cool, 2-pipe systems.
  • Heat-off-cool, 4-pipe systems.
  • Setpoint knob.
  • High quality bi-metal sensor for close temperature differential.

Valves and Actuators

Designed and used for control of heat or cool water flow.

Fan coil valves (zone valves) together with fan coil actuator
used as control device.

Fan Coil Valves

  • 2-way, 3-way, 3-way with 4-ports.
  • DN10 (3/8”), DN15 (1/2”) and DN20 (¾”).
  • PN16.
  • Kvs 0.4, 0.6, 1.0, 1.6, 2.5, 3.5, 4.0 and 5.0.
  • Stroke 3.7 mm.
  • Normally Open Valves.

Fan Coil Actuators

  • Control Signal on/off or Pulse Width Modulating (PWM).
  • 24 Vac/dc and 220 Vac versions.
  • Normally Open and Normally Closed versions.
  • Stroke 4.0 mm
  • Adaptors to motorize other valve brands.
  • Actuator with control signal 0-10 Vdc also available.

Damper Actuators

  • To be used for positioning of dampers,
  • Spring Return Damper Actuators and Non-Spring Return Damper Actuators.
  • Torque 2, Nm, 4 Nm,  5Nm, 8 Nm, 10 Nm, 15 Nm, 16 Nm, 24 Nm and 32 Nm.
  • Control signals on/off, 3-point, 2-10 Vdc or 4-20 mA.

Weather

Weather Sensor Shields

  • Used in outdoor installations to protect relative humidity and temperature sensor from rain and sun radiation ensuring reliable measurement data.
  • Maximum protection from solar radiation and precipitation.
  • To be assemblied on wall or on mast.

Wind Speed and Wind Speed/Direction Sensors

  • The sensors accurately measures the wind speed and direction, providing output signals compatible with most DDC controllers.
  • Intended for applications where external weather conditions influence the building control strategy, such as for the automatic closing of windows in high wind conditions.
  • To be assemblied on wall or on mast.

Weather Station Products

  • Other weather station and meteorology products on request
  • rain detectors, aerodynamic rain gauges, sunshine detectors, lighting detectors, vane anemometers, barometric measurement etc
Facebook